Fluke IDA-5

Medical test and inspection equipment

Fluke IDA-5

1-4 channel infusion test device

Art. No. 546-4349396 (1-channel)
Art. No. 546-4349482 (2-channel)
Art. No. 546-4349591 (4-channel)


Fluke Biomedical’s IDA-5 is based on advanced measurement technology trusted by biomedical experts for over 20 years. The IDA-5 is a fully functional device for measuring instantaneous, average, occlusion and double flow rates according to IEC60601-2-24.

Product advantages

  • Multi-channel infusion device analyzer that can test up to 4 infusion pumps simultaneously
  • Integrated automation for creating user-defined test templates in accordance with IEC60601-2-24
  • Fast, standardized testing of infusion pump devices

Main features‍‍‍

  • User-defined test templates for quick and standardized tests
  • Compatible with practically all infusion devices
  • Snapshots of flow and pressure in real time for immediate detection of problems
  • Instantaneous and average flow measurement of up to 1500 ml/h
  • Occlusion pressure measurements up to 45 psi
  • Single and double flow-through tests (piggyback tests) and PCA tests
  • To maximize test accuracy, the device only starts the test when liquid is present
  • Automatic termination of flow measurement based on time, volume or both – user adjustable
  • Convenient and easy data entry via plug-and-play, USB-compatible keyboard or barcode scanner
  • Integrated memory for saving the test results for printing or downloading to the computer
  • Optional automation software for complete integration of the device test, including electrical safety
  • Visual inspection and other performance parameters for complete digital data management

The IDA-5 is based on advanced measurement technology trusted by biomedical experts for more than 20 years. It is a fully functional device that measures instantaneous, average, occlusion and double flow rates based on IEC60601-2-24.

Videos


Request now

Contact us

Further infusion test devices:



Fluke IDA-6

Medical test and inspection equipment

Fluke IDA-6

1-4 channel infusion analyzer

Art. No.546-5329703 – IDA-6/1, One-Channel Infusion Device Analyzer
Art. No. 546-5329715- IDA-6/2, Two-Channel Infusion Device Analyzer
Art. No. 546-5329726 – IDA-6/4, Four-Channel Infusion Device Analyzer


Fluke Biomedical’s IDA-6 Infusion Device Analyzer redefines infusion device testing.
This state-of-the-art device, integrated with powerful OneQA Workflow Autonation software, revolutionizes infusion device performance testing by providing unprecedented accuracy, efficiency and automation.

Product advantages

  • Unsurpassed speed through access to proprietary OneQA software
  • Automatic storage of results with simultaneous synchronization with the PC
  • Intuitive user interface

Main features

  • No priming required, reduces the complexity of setup and testing
  • Closed test circuit, i.e. testing without chaos
  • 100 times faster than IDA-5 at low flow rates
  • Removable channels simplify calibration and eliminate downtime‍
  • Increase productivity and maximize compliance from a central location with access to OneQA
  • Standardization and process management
  • Documentation and reporting
  • Automation and efficiency‍

Videos


Request now

Contact us

Further infusion test devices:



Fluke IDA-1S

Medical test and inspection equipment

Fluke IDA-1S

Portable, battery-operated infusion test device

Art. No. 546-4468525


The IDA-1S from Fluke Biomedical is a portable, battery-powered test device that can be used to check the performance of infusion devices in the shortest possible time.
Weighing less than 1.3 kg, the analyzer is ideal for quick and reliable single-channel measurements on the go.

Product advantages

  • Portable, ultra-light and powerful for on the go
  • Simple operation thanks to LCD touchscreen
  • Built-in rechargeable battery for up to 10 hours of continuous operation

Main features

  • Measures average and instantaneous flow rate
  • Enables measurement to start from the smallest detected flow rate
  • Pressure measurements (occlusion) up to 45 psi (approx. 3’102mbar)
  • Maximized accuracy with auto-start mode
  • Can be used with a variety of infusion and syringe pumps
  • Sophisticated, globally trusted measurement technology
  • Integrated memory function
  • Hydrograph software for controlling and storing tests

The IDA-1S is also suitable for simple test measurements on infusion devices, such as measuring the flow rate and flow volume. In addition, the device can also be used to measure the pressure that occurs when the fluid channel is closed or blocked.

The IDA-1S is equipped with integrated hydrograph software and can be used to test a variety of different infusion pumps. The IDA-1S has been developed with state-of-the-art measurement technology trusted by biomedical experts worldwide.

The device is easy to install, simple to use and the integrated data memory allows instant storage of test results. It is battery powered, lasts for 10 hours of continuous operation and is therefore ideal for test measurements on the move.

The autostart function simplifies the performance of syringe pump and other tests that require a longer start-up time.

Videos


Request now

Contact us

Further infusion test devices: